IEC 60529 testing determines the ability of an enclosure to protect its contents from contaminants. A contaminant can be either a solid or a liquid. This testing is known as ingress protection tests or IP Code tests. The Ingress Protection Rating or IP Code consists of the letters “IP” and then either two digits or one digit and one letter. There can also be an additional optional letter. The first digit is the protection from solid particles. The second digit is the protection from liquids. The requirements of IEC 60529 testing are identical to those detailed in EN 60529 testing.
Each test in EN 60529 & IEC 60529 ingress protection testing specifies parameters. For example, the size of the solid particle can vary based on the rating. For IP Code water testing, the duration, flow rate, temperature, depth and angle of the water is spelled out. The water testing can be a drip, spray, splash or immersion.
The definition of successfully meeting the EN 60529 & IEC 60529 test requirements is vague. The determination is usually left to the manufacturer. Some enclosures can have zero ingress. Conversely, it is common for some ingress to occur and enclosure to have met the requirements. This occurs when the device continues to properly operate despite some ingress. The definition largely depends on what the product is and what it is being used for.
Included below are the various test levels and definitions for solid objects. These represent the first number in the IP Code.
Level
|
Object size protected against
|
Effective against
|
0
|
No protection against contact and ingress of objects
|
|
1
|
>50 mm
|
Any large surface of the body, such as the back of a hand, but no protection against deliberate contact with a body part
|
2
|
>12.5 mm
|
Fingers or similar objects
|
3
|
>2.5 mm
|
Tools, thick wires, etc.
|
4
|
>1 mm
|
Most wires, screws, etc.
|
5
|
Dust protected
|
Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment; complete protection against contact
|
6
|
Dust tight
|
No ingress of dust; complete protection against contact
|
The second digit indicates the level or protection that the enclosure provides against access to hazardous parts and the ingress of water.
Level
|
Protected against
|
Testing for
|
Details
|
0
|
Not protected
|
||
1
|
Dripping water
|
Dripping water (vertically falling drops) shall have no harmful effect.
|
Test duration: 10 minutes Water equivalent to 1mm rainfall per minute |
2
|
Dripping water when tilted up to 15°
|
Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle up to 15° from its normal position.
|
Test duration: 10 minutes Water equivalent to 3mm rainfall per minute |
3
|
Spraying water
|
Water falling as a spray at any angle up to 60° from the vertical shall have no harmful effect.
|
Test duration: 5 minutes Water volume: 0.7 litres per minute Pressure: 80–100 kN/m² |
4
|
Splashing water
|
Water splashing against the enclosure from any direction shall have no harmful effect.
|
Test duration: 5 minutes Water volume: 10 litres per minute Pressure: 80–100 kN/m² |
5
|
Water jets
|
Water projected by a nozzle (6.3mm) against enclosure from any direction shall have no harmful effects.
|
Test duration: at least 3 minutes Water volume: 12.5 litres per minute Pressure: 30 kN/m² at distance of 3m |
6
|
Powerful water jets
|
Water projected in powerful jets (12.5mm nozzle) against the enclosure from any direction shall have no harmful effects.
|
Test duration: at least 3 minutes Water volume: 100 litres per minute Pressure: 100 kN/m² at distance of 3m |
7
|
Immersion up to 1 m
|
Ingress of water in harmful quantity shall not be possible when the enclosure is immersed in water under defined conditions of pressure and time (up to 1 m of submersion).
|
Test duration: 30 minutes Immersion at depth of 1m |
8
|
Immersion beyond 1 m
|
The equipment is suitable for continuous immersion in water under conditions which shall be specified by the manufacturer. Normally, this will mean that the equipment is hermetically sealed. However, with certain types of equipment, it can mean that water can enter but only in such a manner that it produces no harmful effects.
|
Test duration: continuous immersion in water Depth specified by manufacturer |
The IP Code can be appended by additional letters. These letters classify the level of protection against hazardous parts by persons. They can also provide additional information related to the protection of the device:
Mechanical Impact Resistance numbers are sometimes used. They identify the energy needed to qualify a specified resistance level. These levels are measured in joules (J). It is important to note that mechanical impact resistance was dropped from the third edition of IEC 60529 onwards.