Writer: admin Time:2021-08-03 11:22 Browse:℃
Standards & Clauses:
IEC 60061-3:2015 “Lamp caps and holers together with gauges for the control of interchangeability and safety –Part 3:Gauges,MOD”
IEC 60238:2017 “Edsion screw lampholders”
IEC 61184:2017 “Bayonet lampholders”
Samples and Restrictions:
Screw, bi-pin, prefocus, miscellaneous, bayonet lamp caps and holders
Application:
To check whether the dimensions and shapes of the lamp caps and holders meet standard requirements by using the various types of lamp caps and lamp holders interchangeable size gauge.
Test Principle:
Measure the shape and size of the lamp cap or holder by using the corresponding gauge, to verify the lamp cap or holder is compliant with the standard range.
Structure:
Please refer to the figures in the standards.
Technical Parameters:
No.: | Category | Name | Standard Figure |
1 | E14 Lamp Cap | E14 Lam Cap “Go” Gauge | 7006-27F-1 |
2 | E14 Lamp Cap “Not Go” Gauge | 7006-28B-1 | |
3 | E14 Lamp Cap Prevent Accidental Contact Gauge | 7006-55-2 | |
4 | E14S1 Lamp Cap “Go” Gauge | 7006-27G-1 | |
5 | E14 Lamp Cap Contacting Making Gauge | 7006-54-2 | |
6 | E14 Lamp Cap Torque Test Gauge | IEC60968Fig2 | |
7 | E27 Lamp Cap | E27 Lam Cap “Go” Gauge | 7006-27B-1 |
8 | E27 Lamp Cap“Not Go” Gauge | 7006-28A-1 | |
9 | E27S1 Lamp Cap “Go” Gauge | 7006-27C-1 | |
10 | E27 Lamp Cap Contacting Making Gauge | 7006-50-1 | |
11 | E27 Lamp Cap Prevent Accidental Contact Gauge | 7006-51A-2 | |
12 | E27 Lamp Cap Prevent accidental contact gauge 51*39 | 7006-51-2 | |
13 | E27 Lamp Cap Torque Test Gauge | IEC60968Fig2 | |
14 | B15 Lamp Cap | B15 Lamp Cap Insertion Gauge | 7006-4A-2 |
15 | B15 Lamp Cap Retention Gauge | 7006-4B-1 | |
16 | B15 Lamp Cap “Not Go” Gauge | 7006-10-8 | |
17 | B15 Lamp Cap “Go” Gauge | 7006-11-8 | |
18 | B15 Lamp Cap Torque Test Gauge | IEC60968Fig3 | |
19 | B22d Lamp Cap | B22 Lamp Cap Insertion Gauge | 7006-4A-2 |
20 | B22 Lamp Cap Retention Gauge | 7006-4B-1 | |
23 | B22 Lamp Cap “Go” Gauge | 7006-10-8 | |
24 | B22 Lamp Cap “Not Go” Gauge | 7006-11-8 | |
25 | B22D Lamp Cap Acceptance Gauge | 7006-3-1 | |
26 | BY22d Lamp Cap “Go” Gauge | 7006-17A-1 | |
27 | B22 Lamp Cap Torque Test Gauge | IEC60968Fig3 | |
28 | GZ10 Lamp Cap | “Go” / “Not Go” Gauge | 7006-120-1 |
29 | GZ10 Lamp Holder | “Go” / “Not Go” Gauge | 7006-120A-1 |
30 | GU10 Lamp Holder | “Go” / “Not Go” Gauge | 7006-121A-1 |
31 | GU10 Lamp Cap | GU10 Lamp Cap “Go” / “Not Go” Gauge | 7006-121-1 |
32 | E26 Lamp Cap | E26 Lamp Cap “Go” Gauge | 7006-27D-3 |
33 | E26 Lamp Cap “Not Go” Gauge | 7006-29L-4 | |
34 | E26d Lamp Cap Prevent Accidental Contact Gauge | 7006-29A-2 | |
35 | E26 Lamp Cap Contacting Making Gauge | 7006-29-3 | |
36 | E26d Lamp Cap Reference Diameter 23mm “Go” Gauge | 7006-29B-2 | |
37 | E26d Lamp Cap Reference Diameter 13.2mm “Go” Gauge | 7006-29C-2 | |
38 | E26d Lamp Cap Reference Diameter 10.4mm “Go” Gauge | 7006-29D-1 | |
39 | E26 Lamp Cap | 7006-27E-1 | |
40 | E14 Lamp Holder | “Go” Gauge | 7006-25-7 |
41 | “Not Go” Gauge | 7006-26-4 | |
42 | Contacting Making Gauge | 7006-30-2 | |
43 | Candle Lamp Contacting Making Gauge | 7006-30A-1 | |
43 | Prevent Accidental Contact Gauge | 7006-31-4 | |
44 | Torque Test Cap | IEC 60238 Figure5 | |
45 | Test Cap "A" | IEC 60238 Figure13 | |
46 | Test Cap "b" | IEC 60238 Figure13 | |
47 | E27 Lamp Holder | “Go” Gauge | 7006-25A-2 |
48 | “Not Go” Gauge | 7006-26-4 | |
49 | Prevent Accidental Contact Gauge | 7006-22A-4 | |
50 | Anti-bulb Neck Damage and Contacting Making Gauge | 7006-21-5 | |
51 | Inside Shrapnel Resilience Gauge | 7006-22D-1 | |
52 | Side Contacts Edge Gauge | 7006-22B-1 | |
53 | Side Contacts Resilience Gauge | 7006-22C-1 | |
54 | Torque Test Cap | IEC 60238 Figure5 | |
55 | Aging test cap | IEC 60238 Figure14 | |
56 | E40 Lamp Cap | “Go” Gauge | 7006-27-7 |
57 | “Not Go” Gauge | 7006-28D-1 | |
58 | Prevent Accidental Contact Gauge | 7006-53-1 | |
59 | Contacting Making Gauge | 7006-52-1 | |
60 |
B22 Lamp Holder
|
Plug Gauge | 7006-12-8 |
61 | Gauge for checking contact position and contact force in (90°-130°) | 7006-15-7 | |
62 | Gauge for checking contact position and contact force(90°-130°) | 7006-20-4 | |
63 | Supplementary “Go” Gauge | 7006-12A-2 | |
64 | “Not Go”/ Retention Gauge | 7006-12B-2 | |
65 | Gauge for checking contact position and contact force | 7006-15A-2 | |
66 | Gauge for the slots in lampholders | 7006-13-5 | |
67 | Plug Gauge | 7006-17B-1 | |
68 |
E12 Lamp Cap
|
“Go” Gauge | 7006-27H-1 |
69 | “Not Go” Gauge | 7006-28C-1 | |
70 | Supplementary “Go” Gauge | 7006-27J-1 | |
71 | Contacting Making Gauge | 7006-32-1 | |
72 |
E17 Lamp Cap
|
“Go” Gauge | 7006-27K-1 |
73 | “Not Go” Gauge | 7006-28F-1 | |
74 | Contacting Making Gauge | 7006-26D-1 | |
75 |
E39 Lamp Cap
|
“Go” Gauge | 7006-24B-1 |
76 | “Not Go” Gauge | 7006-24C-1 | |
77 | Contacting Making Gauge | 7006-24A-1 | |
78 | E40 Lamp Holder | “Go” Gauge | 7006-25-7 |
79 | “Not Go” Gauge | 7006-26-4 | |
80 | Prevent Accidental Contact Gauge | 7006-24-3 | |
81 | Contacting Making Gauge | 7006-23-3 | |
82 | 1EP10 Lamp Cap | “Not Go” Gauge | 7006-28-7 |
83 | 2EP10 Lamp Cap | “Go” Gauge | 7006-37-1 |
84 | 3EY10 Lamp Cap | “Go” Gauge | 7006-7-1 |
85 | 4E10 Lamp Cap | “Go” Gauge | 7006-27A-2 |
86 |
G5 Lamp Cap
|
“Go” and “Not Go” Gauge for Unfinished Bi-pin Cap | 7006-46-3 |
87 | “Go” Gauge for Bi-pin Cap on Finished Lamps | 7006-46A-3 | |
88 |
G13 Lamp Cap
|
“Go” and “Not Go” Gauge for Unfinished Bi-pin Cap | 7006-44-4 |
89 | “Go” Gauge for Bi-pin Cap on Finished Lamps | 7006-45-4 | |
90 |
G5 Lamp Holder
|
Contacting Making Plug Gauge for Finished Lamps | 7006-47A-2 |
91 | Double Ended Gauge | 7006-47B-3 III IV V | |
92 | Double Ended “Go” Gauge | 7006-47B-3 I II | |
93 |
G13 Lamp Holder
|
Double Ended Gauge | 7006-60B-4 III IV V |
94 | Double Ended “Go” Gauge | 7006-60C-3 I II | |
95 |
GU5.3 Lamp Holder
|
“Go” Gauge | 7006-73A-1 |
96 | Gauge A | 7006-73A-2 | |
97 | Gauge B | 7006-126B-1 | |
98 |
G9 Lamp Cap
|
“Go” Gauge | 7006-129-1 |
99 | “Not Go” Gauge | 7006-129A-1 | |
100 | G5.3 Lamp Cap | Gauge for Bi-pin Cap G5.3 on Finished Lamps | 7006-73-1 |
101 | GU5.3 | “Go” and “Not Go” Gauge for Bi-pin Base | 7006-109-1 |
102 | GX5.3 | “Go” and “Not Go” Gauge for Bi-pin Base | 7006-73B-2 |
103 | GY5.3 | “Go” and “Not Go” Gauge for Bi-pin Base | 7006-73C-2 |
104 | 2G10 | “Go” Gauge for Caps on Finished Lamps | 7006-118-1 |
105 |
GX10q
|
“Go” Gauge for Caps on Finished Lamps | 7006-84-2 |
106 | “Not Go” Gauge A for Caps on Finished Lamps | 7006-84A-1 | |
107 | “Not Go” Gauge B for Caps on Finished Lamps | 7006-84B-1 | |
108 | “Go” Gauges for Keys on Finished Lamps | 7006-84E-1 | |
109 | “Not Go” Gauges for Caps on Finished Lamps | 7006-84F-1 | |
110 |
GY10q |
“Go” Gauge for Caps on Finished Lamps | 7006-85-2 |
111 | “Not Go” Gauge A for Caps on Finished Lamps | 7006-85A-1 | |
112 | “Go” Gauges for Keys on Finished Lamps | 7006-85D-1 | |
113 | “Not Go” Gauges for Caps on Finished Lamps | 7006-85E-1 | |
114 | G10q, GY10q | “Go” Gauge | 7006-79-2 |
115 | G12 | “Go” Gauge for Caps on Finished Lamps | 7006-80-1 |
116 | PG12,PGX12 Lamp Cap | “Go” Gauge | 7006-81-3 |
117 | Fc2 Lamp Cap | “Go” Gauge | 7006-114-1 |
118 | GR8 | “Go” Gauge for Caps on Finished Lamps | 7006-68-2 |
119 | GR8 | Gauge for caps to ensure entry of maximum lampholders and to check pin-spacing and length | 7006-68A-2 |
120 | GR8,GR10q | “Go” Gauge for checking the pins of caps on finished lamps | 7006-68E-1 |
121 | GR8,GR10q | “Go” and “Not Go” Gauge for checking the pins of caps | 7006-68F-1 |
122 | 2G13 Lamp Cap | “Go” Gauge | 7006-33-2 |
123 | 2G72GX7 Lamp Cap | “Go” and “Not Go” Gauge | 7006-102-1 |
124 | G23 Lamp Cap | “Go” and “Not Go” Gauge | 7006-69-2 |
125 | GX23 Lamp Cap | “Go” and “Not Go” Gauge | 7006-86-1 |
126 | G24GX24 Lamp Cap | “Go” and “Not Go” Gauge | 7006-78-3 |
127 | GX32 Lamp Cap | “Go” and “Not Go” Gauge | 7006-87-2 |
128 | G4 | “Go” and “Not Go” Gauge for Bi-pin Lamp Bases | 7006-72-1 A B |
129 | GU4 | “Go” and “Not Go” Gauge for Bi-pin Lamp Bases | 7006-108-2 |
130 | GZ4 | “Go” and “Not Go” Gauge for Bi-pin Lamp Bases | 7006-67-1 |
131 | G6.35GX6.35GY6.35GZ6.35 | “Go” and “Not Go” Gauge for Bi-pin Bases | 7006-61-5 |
132 | G6.35GX6.35GY6.35 | “Go” Gauge for Bi-pin Bases | 7006-61A-3 |
133 | GZ6.35 | “Go” Gauge for Bi-pin Bases | 7006-59B-1 |
134 | GU7 | “Go” and “Not Go” Gauge for Bi-pin Bases | 7006-113-2 |
135 | R17d | “Go” and “Not Go” Gauge | 7006-57-3 |
136 | Fa6 | “Go” and “Not Go” Gauge | 7006-41-2 |
137 | Fa8 | “Go” Gauge | 7006-40-1 |
138 | Fa8 | “Not Go” Gauge | 7006-40A-1 |
139 | 2G11 | “Go” Gauge | 7006-82-1 |
140 | B15 Lamp Holder | “Go” Gauge | 7006-12D-2 |
141 |
B15d Lamp Holder
|
“Not Go” Gauge | 7006-12C-2 |
142 | Gauge for checking contact position and contact force in bayonet lampholders | 7006-15B-1 | |
143 | Gauges for the slots in the lampholders | 7006-13-5 | |
144 |
E17 Lamp Holder
|
“Go” Gauge | 7006-25H-1 |
145 | “Not Go” Gauge | 7006-26C-1 | |
146 | Gauges for testing contact-making in lampholers | 7006-26E-1 | |
147 | E26 | “Go” Gauge | 7006-25B-2 |
148 | E26&E26d | “Not Go” Gauge | 7006-26A-2 |
149 | E26d | Plug gauge for testing protection against accidental contact in E26d lampholder | 7006-29J-1 |
150 |
G6.35 Lamp Holder
|
Min. Retention Gauge | 7006-61C-4 |
151 | “Go” Gauge | 7006-61B-4 | |
152 |
G12 Lamp Holder
|
“Go” Gauge A | 7006-80A-2 |
153 | “Go” Gauge B | 7006-80B-2 | |
154 | “Go” Gauge C | 7006-80C-2 | |
155 | “Go” Gauge D | 7006-80D-3 | |
156 | “Go” Gauge E | 7006-80E-3 | |
157 | R7S | Gauges for testing contact-making | 7006-62-4 |
158 | G5.3 Lamp Holder | “Go” Gauge | 7006-73A-1 |
159 |
GX53 Lamp Holder
|
“Go” Gauge A | 7006-142A-1 |
160 | “Go” Gauge B | 7006-142B-1 | |
161 | “Go” Gauge C | 7006-142C-1 | |
162 | “Go” and “Not Go” Gauge | 7006-142G-1 | |
163 | “Not Go” Gauge | 7006-142H-1 | |
164 | R7S Lamp Holder | “Go” Gauge | 7006-62-1 |
165 | GX5 Lamp Holder | “Not Go” Gauge | 7006-142J-1 |
166 | E5 Lamp Holder | “Go” Gauge | 7006-25F-1 |
167 | “Not Go” Gauge | 7006-25G-1 | |
168 | E10 Lamp Holder | “Go” Gauge | 7006-25-7 |
169 | EP10 Lamp Holder | “Go” Gauge | 7006-37A-1 |
170 | E10 Lamp Holder | “Not Go” Gauge | 7006-26-4 |
171 | EY10 Lamp Holder | “Not Go” Gauge | 7006-26-4 |
172 | EP10 Lamp Holder | “Not Go” Gauge | 7006-26-4 |
173 | EY10 Lamp Holder | “Go” Gauge | 7006-7A-1 |
174 | E11 Lamp Holder | Gauges A for testing contact-making | 7006-6A-1 |
175 | Gauges B for testing contact-making | 7006-6B-1 | |
176 | E12 Lamp Holder | “Go” Gauge | 7006-25C-1 |
177 | “Not Go” Gauge | 7006-26B-1 | |
178 | Contact-making | 7006-32A-1 | |
179 | E17 Lamp Holder | “Go” Gauge | 7006-25H-1 |
180 | “Not Go” Gauge | 7006-26C-1 | |
181 | Gauges for testing contact-making | 7006-26E-1 | |
182 | E26 Lamp Holder | “Go” Gauge | 7006-25B-2 |
183 | “Not Go” Gauge | 7006-26A-2 | |
184 | E26d Lamp Holder | “Not Go” Gauge | 7006-26A-2 |
185 | E26 Lamp Holder | Gauges for testing contact-making | 7006-25J-1 |
186 |
E26d Lamp Holder
|
“Go” Gauge | 7006-29K-1 |
187 | Gauges for testing contact-making | 7006-29G-3 | |
188 | Gauge for checking the radial position of the intermediate contact of lampholder | 7006-29E-1 | |
189 | Gauge for testing the relative positions of the contacts in lampholder | 7006-29F-1 | |
190 | Gauge for testing contact-making in metal-shell paper-lined lampholders | 7006-29H-3 | |
191 | Plug gauge for testing protection against accidental contact | 7006-29J-1 | |
192 | Gauge for testing unacceptable contact-making in lampholders | 7006-29M-1 | |
193 | E39 Lamp Holder | “Go” Gauge | 7006-24E-1 |
194 | “Not Go” Gauge | 7006-26-4 | |
195 | Gauges for testing contact-making | 7006-24D-1 | |
196 | Gauge for testing maximum insertion torque in lampholders with shell-grip features | 7006-24F-1 | |
197 | Gauge for testing minimum insertion torque in lampholders with shell-grip features | 7006-24G-1 | |
198 | E40 Lamp Holder | “Go” Gauge | 7006-25-7 |
199 | “Not Go” Gauge | 7006-26-4 | |
200 | Gauges for testing contact-making | 7006-23-3 | |
201 | Plug gauge for lampholders for testing protection against accidental contact | 7006-24-3 | |
202 | Torque Test Cap | IEC 60238 Figure5 | |
203 | GX53 Lamp Cap | “Go” and “Not Go” Gauge | 7006-142-1 |
204 | “Not Go” Gauge | 7006-142D-1 | |
205 | “Go” and “Not Go” Gauge for checking keyways in caps | 7006-142E-1 | |
206 | “Not Go” Gauge for checking keyways in caps | 7006-142F-1 |
Contact: Nina She
Email: sales@china-gauges.com
Tel: +86-755-33168386
Skype: nina.she@outlook.com
Address: 1F Junfeng Building, Gongle, Xixiang, Baoan District, Shenzhen, Guangdong, China